Vickers 4525V42A21-1DA22R V Series Double Vane Pump
category
vane pumps
Vickers 4525V42A21-1DA22R Bearing SPECIFICATIONS
Vickers
4525V42A21-1DA22R
kamenzhangChina
kamenzhang2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
Price
Inspection Certificate
Product Specifications
Company Profile
Vickers 4525V42A21-1DA22R Ürün Açıklaması
Vickers offers the most complete line of hydraulic intravane pumps
for industrial applications. A wide variety of single and multiple
configurations enables you to select the precise pump or
combination best suited for your application.Your choice of pump is backed by more than 70 years of Vickers
engineering and manufacturing skill.PerformanceThese cost–effective pumps provide volumetric efficiencies of more
than 90% and sound levels as low as 62 dB(A) with operating
pressures to 207 bar (3000 psi).General DescriptionIntravane pumps provide longer life, increased productivity and
application versatility. Extremely low sound levels are compatible
with the most demanding industrial applications.Compact size and ease of service allow maximum equipment design
flexibility. Pumps are available in single, double and thru-drive
configurations.Ordering Code:The common pump model no# we have stock:
2520V17A14-1AA22R
4525V50A21-1AA22R
2520V17A8-1CC22L
4525V50A21-1AB22R
2520V17A8-1CC22R
4525V50A21-1AD22R
2520V21A11-1AB22R
4525V50A21-1BA22L
2520V21A12 1AA22R
4525V50A21-1BB22L
2520V21A5-1CC-22R
4525V50A21-1CC22R
2520V21AB-1CC22R
4525V50A21-1CC22R
3520V25A11-1BB22R
4525V50A21-1DA22R
3525V25A14-1BB22R
4525V50A21-1DC22R
3525V25A17-1BB22R
4525V50A21-1DD22R
3525V38A12-1BB22R
4525V50A21-86AA22R
3525V38A21-86BA22R
4525V50A21-86BB22R
4525V42A14-1AD22R
4525V60A12-1AA22R
4525V42A17-1AA22R
4525V60A12-1CC22L
4525V42A17-1CC22R
4525V60A12-1CC22R
4525V42A17-1DA22R
4525V60A12-1DD22R
4525V42A17-1DD22R
4525V60A14-1BA22R
4525V42A21-1AA22R
4525V60A17-1AA22R
4525V42A21-1BA22R
4525V60A17-1CC22L
4525V42A21-1BB22R
4525V60A17-1CC22R
4525V42A21-1BD22R
4525V60A21-1AA22R
4525V42A21-1CC22R
4525V60A21-1BA22R
4525V42A21-1DA22R
4525V60A21-1BD22R
4525V42A21-86AA22R
4525V60A21-1CC22R
4525V42A21-86CC22R
4525V60A21-1DA22R
4525V42A21-86DD22R
4525V60A21-1DD22L
4525V50A12-1DD22R
4525V60A21-1DD22R
4525V50A14-1AA22R
4525V60A21-86AA22R
4525V50A14-1DD22R
4535V50A30-86BB22R
4525V50A17-1AA22R
4535V50A35-86DD22R
4525V50A17-1CC22R
4535V60A35-1DA22R
4525V50A17-1DD22R
4535V60A35-86BB22R
vane pumps Vickers 4525V42A21-1DA22R V Series Double Vane Pump
Double vane pump works: it consists of stator, rotor, blade and oil pan and other components. The inner wall of the stator is approximately elliptical. The blade is mounted in the radial groove of the rotor and slides along the groove, and the rotor is mounted concentrically with the stator. When the rotor is rotated, the blade is pressed against the inner surface of the stator under the action of centrifugal force, and is forced to reciprocate in the rotor tank with the change of the inner surface curve of the stator, and the sealing working chamber between adjacent two blades is enlarged and shrunk Variety. When the blade is slid from a small radius arc to a large radius arc, the sealed working chamber gradually increases to form a local vacuum, and the oil in the tank is sucked through the oil suction chamber through the oil pan; Rotate the rotor every week, the blade in the tank to slip back and forth 2 times to complete the 2 oil and 2 times the pressure oil, and the pressure generated by the radial force is balanced, so called double acting, also known as balanced.
Single acting vane pump works: mainly by the stator, rotor, blade and oil pan and other components. The inner surface of the stator is a cylindrical shape, the rotor is eccentrically mounted in the stator, that is, an eccentric e, the blade is mounted in the rotor radial chute and slid radially within the slot. Rotor rotation, the centrifugal force and the role of the root pressure of the blade under the action of the blade close to the inner surface of the stator, so that between the two adjacent leaves to form a sealed working chamber. In one side, the blade gradually extended, sealed working chamber gradually increased, the formation of local vacuum, the formation of oil; the other hand, the other side, the formation of oil. Rotate each turn a week, the blade in the chute reciprocating slip 1 times to complete a suction oil pressure. Oil pressure generated by the radial force is not balanced, so called single acting, also known as unbalanced vane pump.
Vane Pumps
Power never sounds better than when it’s quiet—that’s why Eaton fixed displacement vane pumps with low-noise characteristics are an excellent choice for a broad range of mobile and industrial applications. Featuring modular designs for flexible displacement, mounting and port options, as well as cartridge kits engineered for easy interchangeability and repair, Eaton vane pumps excel globally in molding, material handling, construction, manufacturing and automotive industries
vane pumps Vickers 4525V42A21-1DA22R V Series Double Vane Pump
Vickers 4525V42A21-1DA22R INTERCHANGE
vane pumps Part series 4525V42A21-1DA22R is a potential replacement for these common bearing part numbers: